Ürünlerimiz

FilmTec™ Seamaxx™-440i

Seawater Extra Low Energy Reverse Osmosis Membrane Element featuring iLEC™ for Low Maintenance Operation
 


 

General Information

  • Keep elements moist at all times after initial wetting.
  • For successful operation of Reverse Osmosis (RO) and Nanofiltration (NF) membrane systems, the operation must follow the guidelines provided in the FilmTec™ Reverse Osmosis / Nanofiltration Elements Operation Excellence and Limiting Conditions Tech Fact .
  • To prevent biological growth during prolonged system shutdowns, it is recommended that membrane elements be immersed in a preservative solution.
  • The customer is fully responsible for the effects of incompatible chemicals and lubricants on elements.
  • Avoid static permeate-side backpressure at all times.
  • Permeate obtained from the first hour of operation should be discarded.
  • The use of this product in and of itself does not necessarily guarantee the removal of cysts and pathogens from water. Effective cyst and pathogen reduction is dependent on the complete system design and on the operation and maintenance of the system.

 


 

Operating and Cleaning Limits
Membrane Type  Polyamide Thin-Film Composite
Maximum Operating Temperature  113°F (45°C)
Maximum Operating Pressure  1200 psig (41 bar)
Maximum Element Pressure Drop
Per element
Per pressure vessel (minimum 4 elements)
15 psig (1.0 bar)
50 psig (3.5 bar)
pH Range
Continuous Operation
Short-Term Cleaning (30 min)
2 – 11
1 – 13
Maximum Feed Silt Density Index (SDI  SDI 5
Free Chlorine Tolerance  < 0.1 ppm