- Keep elements moist at all times after initial wetting.
- For successful operation of Reverse Osmosis (RO) and Nanofiltration (NF) membrane systems, the operation must follow the guidelines provided in the FilmTec™ Reverse Osmosis / Nanofiltration Elements Operation Excellence and Limiting Conditions Tech Fact.
Operating and Cleaning Limits | |
---|---|
Membrane Type | Polyamide Thin-Film Composite |
Maximum Operating Temperature | 113°F (45°C) |
Maximum Sanitization Temperature (@ 25 psig) | 185°F (85°C) |
Maximum Operating Pressure | 600 psig (41 bar) |
Maximum Pressure Drop Per Element Per Vessel (Housing) |
15 psig (1.0 bar) 60 psig (4.1 bar) |
pH Range Continuous Operation Short-Term Cleaning (30 min) |
2 – 11 1 – 12 |
Maximum Feed Silt Density Index (SDI | SDI 5 |
Free Chlorine Tolerance | < 0.1 ppm |